Model | MDR-60-5 | MDR-60-12 | MDR-60-24 | |
Output | DC output Voltage | 5V | 12V | 24V |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 12A | 5A | 2.5A | |
Related Power | 60w | 60w | 60w | |
Wave&Noise | 80mVp-p | 120mVp-p | 150mVp-p | |
Voltage adjust range | 5-6V | 12-15V | 48-56V | |
Set up,rise time | 500ms 30ms/230VAC 1000ms,30ms/115VAC at full load | |||
hold up time | 50ms/230VAC 20ms/115VAC at full load | |||
Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | ||
Input Current | 0.55A/115VAC 0.35A/230VAC | |||
Efficiency | 77% | 81% | 84% | |
AC inrush current | Cold start current 35A/115V 70A/230VAC | |||
Leakage current | <1mA/240VAC | |||
Protection | Overload | Above 105%-160% rated output power | ||
hiccup mode, recovery automatically after fault condistion is removed | ||||
Over voltage | 6.25-7.25V | 15.6-18V | 57.6-64.8V | |
Shut down o/p voltage, re-power on to recover | ||||
Function | DC OK active single | Relay contact rating(max) :30V/1A resistive | ||
Environment | Working temp humidity | -20~+70°C 20%~90%RH | ||
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |||
Safety | safety standards | UL508,TUV EN60950-1 approved | ||
Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVA O/P-FG:0.5KVA | |||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25 %RH | |||
EMC emission | Compliance to EN55011,EN55022,EN61204-3 class B,EN61000-3-2,-3 | |||
Size | size | 40*90*100mm W*H*D | ||
Package | 0.45kg, |
No. 108 Liuwengdong Rd, ShangChi Economic Development Area,Liushi Yueqing Wenzhou, Zhejiang, China
+86-18815133343
+86-13645875558