DR-15
FUNELEC
MODEL | DR-15-5 | DR-15-12 | DR-15-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V |
RATED CURRENT | 3A | 1.25A | 0.63A | |
RATED POWER | 15W | 15W | 15W | |
RIPPLE&NOISE | 80mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ.RANGE | 4.75-5.5V | 10.8-13.2V | 21.6-26.4V | |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 100ms,30ms/230VAC 100ms,30ms/115VAC at full load | |||
HOLD UP TIME(TYP.) | 90ms/230VAC 12ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE | 85-264VAC 120-370VDC | ||
FREQUENCY RANGE | 47-63HZ | |||
EFFICIENCY(Typ.) | 74% | 81% | 83% | |
AC CURRENT(Typ.) | 0.88A/115VAC 0.48A/230VAC | |||
INRUSH CURRENT | COLD START 15A/115VAC 30A/230VAC | |||
PROTECTION | OVERLOAD | 105-160% RATED OUTPUT POWER | ||
Protection type:Hiccup mode,recovers automatically after fault condition | ||||
OVER VOLTAGE | 5.75V-6.75V | 13.8V-16.2V | 27.6V-32.4V | |
Protection type:Hiccup mode,recovers automatically after fault condition | ||||
ENVIRONMENT | WORKING TEMP | -10~+60°C | ||
WORKING HUMIDITY | 20-90%RH non-condesing | |||
STORAGE TEMP,HUMIDITY | -20~+85°C,10-95%RH | |||
TEMP.COEFFICIENT | ±0.03%°C(0-50°C) | |||
VIBRATION | 10-500HZ | |||
SAFETY&EMC | SAFETY STANDARD | CE RoHS | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute | |||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70%RH | |||
EMI CONDUCTION&RADIATION | Design refer to GB4943,UL60950,EN60950 | |||
EMC STANDARD | Design refer to GB9254,EN55022 Class A | |||
DIMENSION | 20*93*56mm | |||
PACKING | 0.1kg, |
MODEL | DR-15-5 | DR-15-12 | DR-15-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V |
RATED CURRENT | 3A | 1.25A | 0.63A | |
RATED POWER | 15W | 15W | 15W | |
RIPPLE&NOISE | 80mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ.RANGE | 4.75-5.5V | 10.8-13.2V | 21.6-26.4V | |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 100ms,30ms/230VAC 100ms,30ms/115VAC at full load | |||
HOLD UP TIME(TYP.) | 90ms/230VAC 12ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE | 85-264VAC 120-370VDC | ||
FREQUENCY RANGE | 47-63HZ | |||
EFFICIENCY(Typ.) | 74% | 81% | 83% | |
AC CURRENT(Typ.) | 0.88A/115VAC 0.48A/230VAC | |||
INRUSH CURRENT | COLD START 15A/115VAC 30A/230VAC | |||
PROTECTION | OVERLOAD | 105-160% RATED OUTPUT POWER | ||
Protection type:Hiccup mode,recovers automatically after fault condition | ||||
OVER VOLTAGE | 5.75V-6.75V | 13.8V-16.2V | 27.6V-32.4V | |
Protection type:Hiccup mode,recovers automatically after fault condition | ||||
ENVIRONMENT | WORKING TEMP | -10~+60°C | ||
WORKING HUMIDITY | 20-90%RH non-condesing | |||
STORAGE TEMP,HUMIDITY | -20~+85°C,10-95%RH | |||
TEMP.COEFFICIENT | ±0.03%°C(0-50°C) | |||
VIBRATION | 10-500HZ | |||
SAFETY&EMC | SAFETY STANDARD | CE RoHS | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute | |||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70%RH | |||
EMI CONDUCTION&RADIATION | Design refer to GB4943,UL60950,EN60950 | |||
EMC STANDARD | Design refer to GB9254,EN55022 Class A | |||
DIMENSION | 20*93*56mm | |||
PACKING | 0.1kg, |
No. 108 Liuwengdong Rd, ShangChi Economic Development Area,Liushi Yueqing Wenzhou, Zhejiang, China
+86-18815133343