DR-240
FUNELEC
Model | DRP-240-12 | DRP-240-24 | DRP-240-36 | DRP-240-48 | |
Output | DC output Voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 20A | 10A | 6.6A | 5A | |
Related Power | 240w | 240w | 240w | 240w | |
Wave&Noise | 80mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 800ms 40ms 20ms | ||||
Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | |||
Input Current | 4.5A/115VAC 0.5A/230VAC | ||||
Efficiency | 80% | 84% | 85%% | 85% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | ||||
Leakage current | <0.5mA/240VAC | ||||
Protection | Overload | Related output power 105-135% start overload protection | |||
Protection type: cutoff output, recovery after restart power | |||||
Over voltage | 13.8V-16.2V | 27.6V-32.4V | 55.2V-64.8V | ||
Hiccup mode,recovers automatically after fault condition | |||||
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |||
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||||
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |||
I/P-FG:1.5KVAC 1min | |||||
O/P-FG:0.5KVAC 1min | |||||
Standard | Safety standard | Fit UL1012 | |||
Refer | Design refer to GB4943,UL60950,EN60950 | ||||
EMC standard | Design refer to GB9254,EN55022 Class A | ||||
Size | size | L125*W100*H125mm | |||
Package | 1.2kg, |
Model | DRP-240-12 | DRP-240-24 | DRP-240-36 | DRP-240-48 | |
Output | DC output Voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 20A | 10A | 6.6A | 5A | |
Related Power | 240w | 240w | 240w | 240w | |
Wave&Noise | 80mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 800ms 40ms 20ms | ||||
Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | |||
Input Current | 4.5A/115VAC 0.5A/230VAC | ||||
Efficiency | 80% | 84% | 85%% | 85% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | ||||
Leakage current | <0.5mA/240VAC | ||||
Protection | Overload | Related output power 105-135% start overload protection | |||
Protection type: cutoff output, recovery after restart power | |||||
Over voltage | 13.8V-16.2V | 27.6V-32.4V | 55.2V-64.8V | ||
Hiccup mode,recovers automatically after fault condition | |||||
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |||
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||||
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |||
I/P-FG:1.5KVAC 1min | |||||
O/P-FG:0.5KVAC 1min | |||||
Standard | Safety standard | Fit UL1012 | |||
Refer | Design refer to GB4943,UL60950,EN60950 | ||||
EMC standard | Design refer to GB9254,EN55022 Class A | ||||
Size | size | L125*W100*H125mm | |||
Package | 1.2kg, |